WPB 820ELEKTRIC BREAST PUMPTIRE-LAIT ELECTRIQUEELEKTRIKLI GÖGÜS POMPASIELEKTRONIK GÖGÜS POMPALARIUSER MANUAL ENMODE D’EMPLOI FRKULLANIM KILAVUZU TRWPB 820 USER MANUALI 1

Content summary on the page No. 2

CONTENTSInstruction manual..............................................................................................................2Parts list...................................................................................................................................4Specification.........................................................................................................................5I - Clean and Sterilize your pump.....................................................

Content summary on the page No. 3

Instruction manualDear breastfeeding mother,In order to use this Electric Breast Pump effectively and safely, please read this manualcarefully, and keep it in a safe place.Important information• Please consult your doctor, lactation consultant, midwife or other breast feedingspecialist to identify whether you are a suitable candidate for breastfeeding using breastpump.• Never immerse the motor unit and AC adapter in water under any circumstances.intelligent• Use only the original attachmen

Content summary on the page No. 4

Breast milk production adjusts to suit daily requirements.The daily amount required by infants can vary considerably. For this reason mothersare often recommended to drink as much as possible at first, in order to stimulate milkproduction.You should pump milk first from one breast, then from the other. However, pumpingshould not exceed 7 minutes for each breast.Breast massage preparationSome Mothers may have difficulty in expressing milk either through using a manualbreast pump or an Electric Pu

Content summary on the page No. 5

• After the hot compression has been completed, massaging the breasts may assist withopening the mammary glands.• Start by placing your thumb and index finger around the base of the nipple and gentlymassage up and down the nipple about 5-6 times for each nipple.• Move to the breast area and gently massage in a circular movement using four fingersflat and your thumb as shown in the picture. Stop after 5-6 rotations on each breast.Note: If you experience pain during massaging or hot compress

Content summary on the page No. 6

1-Breast Pump Parta) Breast shieldb) Pump motorc) Valved) Diaphragme) Adaptorf) Feeding Bottleg) Baseh) Nipple CoverDescription of the electrical properties1- Battery Voltage : 4.5 VDC2 - Battery Capacity : 850mAh3 - Adapter Charger StandardsInput : AC100V-240VOutput: 4.5 VDC, 0.5A4 - Charging Time : about 2,5 hoursSpecificationI - Clean and Sterilize your pumpPlease clean and sterilize your pump before first usage.6 I WPB 820 USER MANUAL

Content summary on the page No. 7

1. Pull the pump motor and put it away from water on a dry place. Do not washthis part or immerse in the water. Use only a soft moist cloth to clean this part.Separate all parts, a.c.d.e.f.g., then wash in warm, soapy water, then rinsethem. Do not use antibacterial or abrasive cleaners/detergents.2. Sterilize all parts in steam sterilizer, or by boiling for 10 minutes. If a steamsterilizer is used, the pump will remain sterile in the sterilizer for minimum 4hours, provided the lid is not removed

Content summary on the page No. 8

III - Assemble your pump Please wash your hands before assembling your breast pump.1. Insert the Diaphragm(d) into the Breast Shield (a)2. Insert the Valve (c) into the Breast Shield (a ) being sure that it fits securelyaround the edge. ( Important! When the valve is lost or not properly installed,the breast pump will not be able to use effectively)3. Insert the feeding bottle (f) into the Breast Shield (a) by rotating it gently toclockwise direction, be sure that it fits securely into the pump

Content summary on the page No. 9

WPB 820 USER MANUALI 9

Content summary on the page No. 10

• Press the start button• Position the Breast shield (Silicone Massage Pad) firmly onto your breast so asto create a perfect seal (do not let air into), you will feel suction on your breast.• By pressing the “+” button, suction and frequency will increase a level.By pressing “-“ button, suction and frequency will reduce a level. Thereare totally seven levels. Be sure your milk flow successfully and position iscomfortable for you.3. Don’t worry if your milk doesn’t flow immediat

Content summary on the page No. 11

3. Placing a warm cloth on your breasts for a few minutes before startingpumping can also encourage your milk flow and soothe painful breasts.4. Warmth and relaxation can help, so you might like to try expressing after awarm bath or shower.5. Try to express from one breast while your baby is feeding from the other, orcontinue expressing just after a feed.6. Repositioning the pump on your breast from time to time can help stimulateyour milk ducts.Practice with your pump to find the best pumping t

Content summary on the page No. 12

time, can soak and thaw in the kettle. After thawing, breast milk can be storedin the refrigerator for 24 hours.6. NEVER refreeze breast milk.7. Frozen breast milk can be heated in warm water or heated with baby bottlewarmer.(Never heat milk in a microwave as this may destroy valuable nutrients andantibodies. In addition, the uneven heating may cause hot spots in the liquidwhich could cause burns in the throat. Never immerse a frozen milk containerin boiling water as this may cause it to crack/s

Content summary on the page No. 13

4. Cracking or discoloration ofpump/bottle parts.• Avoid contact with antibacterial or abrasivedetergents/cleaners as they can damage theplastic. Combinations of detergents, cleaningproducts, sterilizing solution, softened waterand temperature fluctuations may, undercertain circumstances, cause the plastic tocrack. If this occurs, do not use the device.The pump body and breast milk containersare dishwasher safe but it may discolor them.Follow guidelines in ‘How to clean and sterilizeyour pum

Content summary on the page No. 14

TABLE DES MATIÈRESListe des composants...........................................................................................................................2Suggestion................................................................................................................................................41 Recharge des batteries du moteur (C) .......................................................................................43 Assemblage du tire-lait..............................

Content summary on the page No. 15

Liste des composants :1 Liste des pièces du Tire-laita. Téterelleb. Moteur de la pompec. Valve (Silica Gel)d. Diaphragmee. Adapteurf. Biberon récepteurg. BaseCaractéristiques électriques1 Voltage batterie : 4.5 VDC2 Capacité Batterie : 850mAh3 Chargeur Adapteur :Input : AC100V-240VOutput: 4.5 VDC, 0.5A4 Temps de charge : environ 3 heures Nettoyer et Stériliser votre tire-laitVous devez nettoyer et stériliser votre tire-lait avant la première utilisation et aprèschaque utilisation.2 I W

Content summary on the page No. 16

Méthode de stérilisation :1. Retirez le moteur (C) et mettez-le à l’écart. Séparez tous les éléments,a.b.d.e.f.h.i.j., puis lavez les à l’eau chaude savonneuse et rincez. N’utilisez pasde produits désinfectants, détergents ou abrasifs.2. Stérilisez tous les éléments dans un stérilisateur, ou faites bouillir pendant 10minutes. Si vous utilisez un stérilisateur, les éléments resterons stériles pendant au moins 4 heures si le couvercle est maintenu fermé.Important: NE JAMA

Content summary on the page No. 17

(Important! En cas de remisage de l’appareil, tous les éléments doivent être nettoyés etstérilisés avant de remiser l’appareil.1 Recharge des batteries du moteur (C)Le bloc moteur doit-être rechargé avant l’utilisation à l’aide du cordon d’alimentationfourni. Le témoin lumineux rouge indique que l’appareil est en cours de charge. Lorsquele témoin rouge s’éteint, c’est que les batteries sont complètement rechargées. L’appareila alors une autonomie de fonctionnement

Content summary on the page No. 18

WPB 820 MODE D’EMPLOII 5

Content summary on the page No. 19

4 Utilisation du tire-lait1. Lavez-vous bien les mains et la poitrine.2. Assurez-vous que le tire-lait soit stérilisé et correctement assemblé.3. Adoptez une position détendue et confortable à l’aide d’un coussin et relaxes-vous.4. Ajuster la puissance et la fréquence d’aspiration :• Mettez en marche l’appareil en appuyant sur le bouton• Appuyez fermement le coussin masseur sur votre poitrine. Le coussin doitadhérer parfaitement à la poitrine afin que l’air ne pénètre pas

Content summary on the page No. 20

5. Il est normal que l’extraction de lait ne commence pas immédiatement. Relaxez-vous et continuez l’expression du lait. En revanche si l’extraction de laitest douloureuse pour votre poitrine, arrêtez d’utiliser l’appareil et demandezl’avis d’un médecin.(Ne prolongez pas l’expression du lait au delà de 5 minutes si vous n’obtenez pas de lait.Dans ce cas essayez d’extraire du lait à un autre moment de la journée).6. En moyenne il faut 8 minutes d’extraction pour obteni